BLOWER UNIT DISASSEMBLY

PROCEDURE


  1. PRECAUTION

    Note

    Make sure to perform initialization after replacing the No. 1 blower damper servo sub-assembly. If initialization is not performed, the air conditioner unit assembly will not perform properly as the air conditioning amplifier assembly will not be able to recognize the position of the No. 1 blower damper servo sub-assembly.

  2. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY


    1. A01RD8K

      Remove the 3 screws and blower motor with fan sub-assembly.

  3. REMOVE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY


    1. A01RAJY

      Remove the 2 screws and No. 1 blower damper servo sub-assembly.