PROCEDURE
PRECAUTION
Note
Make sure to perform initialization after replacing the No. 1 blower damper servo sub-assembly. If initialization is not performed, the air conditioner unit assembly will not perform properly as the air conditioning amplifier assembly will not be able to recognize the position of the No. 1 blower damper servo sub-assembly.
REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY
Remove the 3 screws and blower motor with fan sub-assembly.
REMOVE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
Remove the 2 screws and No. 1 blower damper servo sub-assembly.