DATA LIST
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Tech Tips
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / IPA/ICS/Clearance Sonar / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| ICS SW Status | Intelligent clearance sonar system switch assembly (Multi-information switch) | OFF or ON | OFF: Intelligent clearance sonar system off ON: Intelligent clearance sonar system on |
- |
| Fr Sensor Onset Range | Detection operation range (for front center sensors) | Narrow or Wide | Narrow: 600 mm (23.6 in.) Wide: 1000 mm (39.4 in.) |
Customized value displayed |
| Rr Sensor Onset Range | Detection operation range (for rear center sensors) | Narrow or Wide | Narrow: 600 mm (23.6 in.) Wide: 1500 mm (59.1 in.) |
Customized value displayed |
| Keep Sense Buzzer | Keep sense buzzer operation | Not Avail or Avail | Not Avail: Buzzer stops Avail: Buzzer sounds continuously |
Customized value displayed |
| Fr & Rr Buzzer Volume | Buzzer volume setting | L, M1, M2, M3 or H | L: Low volume M1: Medium low volume M2: Medium volume M3: Medium high volume H: High volume |
Customized value displayed |
| Sensor Condition N | Front sensor operation | Not Avail or Avail | Not Avail: Front sensors not available Avail: Front sensors available |
Customized value displayed |
| Approach Display OFF | Whether the display turns off after an obstacle is no longer detected. | Not Avail or Avail | Not Avail: Not displayed Avail: Displayed |
Customized value displayed |
| BSM Radar Communication Invalid History | BSM radar communication invalid history | Yes or No | Yes: History stored No: History not stored |
- |
| Target 1 Distance (FLC Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance |
- |
| Target 1 Distance (FRC Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance |
- |
| Target 1 Distance (RLC Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance |
- |
| Target 1 Distance (RRC Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance |
- |
| Target 1 Distance (FL Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 5.10 m | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance |
- |
| Target 1 Distance (FR Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance |
- |
| Target 1 Distance (RL Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance |
- |
| Target 1 Distance (RR Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance |
- |
| Target 2 Distance (FLC Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 7.65 m | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance |
- |
| Target 2 Distance (FRC Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance |
- |
| Target 2 Distance (RLC Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance |
- |
| Target 2 Distance (RRC Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 7.65 m (0.00 to 25.09 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 7.65 m (0.00 to 25.09 ft.): Detected distance |
- |
| Target 2 Distance (FL Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance |
- |
| Target 2 Distance (FR Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance |
- |
| Target 2 Distance (RL Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance |
- |
| Target 2 Distance (RR Sensor) | Distance between ultrasonic sensor and target object | Unknown, Not Detected or 0.00 to 5.10 m (0.00 to 16.73 ft.) | Unknown: Detection conditions not met Not Detected: No objects detected 0.00 to 5.10 m (0.00 to 16.73 ft.): Detected distance |
- |
| ICS Function | Current setting of intelligent clearance sonar system | ON or OFF | ON: Intelligent clearance sonar system enabled OFF: Intelligent clearance sonar system disabled |
Customized value displayed |
| ICS System | Existence of intelligent clearance sonar system | Without or With | Without: w/o Intelligent clearance sonar system With: w/ Intelligent clearance sonar system |
- |
| ICS Stop Distance | Target stop distance | Short or Long | Short: Near Long: Far |
Customized value displayed |
| ICS SW Status Memory | Setting that determines if the on/off operation state when the engine switch is turned off is resumed when the engine switch is turned on | Yes or No | Yes: Previous on/off operation state is resumed No: System operates when the engine switch is turned on |
Customized value displayed |
| Bumper Type | Registered bumper type | Unfixed or 1 to 127 | 1: Bumper for bar type radiator grille 2: Bumper for mesh type radiator grille 3 to 127: Unknown Unfixed: Unknown |
- |
| RCTB Function | Setting of the rear crossing traffic auto brake function | ON/OFF | ON: Rear crossing traffic auto brake function ON OFF: Rear crossing traffic auto brake function OFF |
Customized value displayed |
| RCTB Operation Timing Setting | Setting of the activation timing of the rear crossing traffic auto brake function | Standard or Late | Late: Late timing Standard: Standard timing |
Customized value displayed |
| RCTB Sensitivity | Setting of the sensitivity of the rear crossing traffic auto brake function | Low or Standard | Standard: Standard sensitivity Low: Low sensitivity |
Customized value displayed |
| # Codes | Number of stored DTCs | min.: 0, max.: 255 | Number of DTCs will be displayed | - |
ACTIVE TEST
Tech Tips
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Enter the following menus: Chassis / ABS/VSC/TRAC / Active Test.
According to the display on the GTS, perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Stop Light Relay | Stop lights | ON / OFF | Test possible at vehicle speed of 0 km/h (0 mph) |
Enter the following menus: Body Electrical / Combination Meter / Active Test.
According to the display on the GTS, perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| ICS OFF Indicator | ICS OFF indicator light | ON / OFF | - |
Enter the following menus: Body Electrical / IPA/ICS/Clearance Sonar / Active Test.
According to the display on the GTS, perform the Active Test.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Buzzer | No. 1 clearance warning buzzer | Stop or Operate | Confirm that the vehicle is stopped and the engine switch is on (IG) |