| DTC Code | DTC Name |
|---|---|
| P280713 | Pressure Control Solenoid "G" Circuit Open |
DESCRIPTION
Changing gears is performed by the ECM turning the shift solenoid valves SL1, SL2, SL3, SL4 and SL5 on and off.
If an open or short occurs in any of the shift solenoid valve circuits, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be driven. If all of the shift solenoid valves are malfunctioning, only the mechanical fluid pressure circuit will function and some manual operation will be possible. If an open or short occurs in a shift solenoid valve circuit, the ECM cuts power to the malfunctioning shift solenoid valve.
Tech Tips
The following table shows normal operation of the shift solenoid valves SL4 when the shift lever is in D.
| Gear | 1st | 2nd | 3rd | 4th | 5th | 6th | 7th | 8th |
|---|---|---|---|---|---|---|---|---|
| Shift Solenoid Valve SL4 | OFF | OFF | OFF | ON | OFF | ON | OFF | OFF |
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P280713 | Pressure Control Solenoid "G" Circuit Open | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
Comes on | DTC stored | SAE Code: P2810 |
MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve SL4 circuit. The ECM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores a DTC.
The ECM performs the fail-safe function and turns the other normal shift solenoid valves on or off. In the case of an open or short circuit, the ECM stops sending current to the open or shorted solenoid.
WIRING DIAGRAM
| *a | Shift Solenoid Valve SL4 |
| *b | Transmission Wire |
CAUTION / NOTICE / HINT
Note
Perform registration and/or initialization when parts related to the automatic transaxle are replaced.
Tech Tips
After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Perform the D Position Shift Test inspection in Road Test.
Check for DTCs again.
PROCEDURE
CHECK HARNESS AND TRANSMISSION WIRE (TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL4) - ECM)
Disconnect the D2 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) Click here |
| OK |
|
REPLACE ECM
Replace the ECM.
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM A/T CODE REGISTRATION Click here |
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
Disconnect the D56 transmission wire connector.
Disconnect the D2 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM) |
| OK |
|
INSPECT SHIFT SOLENOID VALVE SL4
| *a | Component without harness connected (Shift Solenoid Valve SL4) |
Remove the shift solenoid valve SL4.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect a positive (+) lead from the battery to terminal 1 and a negative (-) lead with a 21 W bulb to terminal 2 of the solenoid valve connector. Check that the valve moves and makes an operating sound.
| OK |
|---|
| Valve moves and makes an operating sound. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPAIR OR REPLACE TRANSMISSION WIRE Click here |
| NG |
|
REPLACE SHIFT SOLENOID VALVE SL4 Click here |