AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P075511

DTC Code DTC Name
P075511 Shift Solenoid "B" Circuit Short to Ground

DESCRIPTION

Changing gears is performed by the ECM turning the shift solenoid valves SL1, SL2, SL3, SL4, SL5, S1 and S2 on and off.

If an open or short occurs in any of the shift solenoid valve circuits, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be driven. If all of the shift solenoid valves are malfunctioning, only the mechanical fluid pressure circuit will function and some manual operation will be possible. If an open or short occurs in a shift solenoid valve circuit, the ECM cuts power to the malfunctioning shift solenoid valve.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P075511 Shift Solenoid "B" Circuit Short to Ground

1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other


  1. Shift solenoid valve S2 is operated

  2. Shift solenoid valve S2 circuit is shorted

  3. Malfunction status occurs 2 times per trip

  4. 1-trip detection logic


  • Shift solenoid valve S2

  • Transmission wire

  • Harness and connector

  • ECM

Does not come on DTC stored

SAE Code:

P0976

MONITOR DESCRIPTION

This DTC indicates a short to ground in the shift solenoid valve S2 circuit. When there is an open or short in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores a DTC.

When the shift solenoid valve S2 is on, if its resistance is 8 Ω or less, the ECM determines there is a short to ground in the shift solenoid valve S2 circuit.

WIRING DIAGRAM

A01VV9GE41
*1 Shift Solenoid Valve S2
*2 Transmission Wire

CAUTION / NOTICE / HINT

Note

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click here

Tech Tips

After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


  1. Perform the D Position Shift Test inspection in Road Test.

    Click here

  2. Check for DTCs again.

    Click here

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE (SHIFT SOLENOID VALVE S2) - ECM)


    1. Disconnect the D2 ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D2-77 (S2) - Body ground 20°C (68°F) 11 to 15 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. REPLACE ECM


    1. Replace the ECM.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  3. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. Disconnect the D56 transmission wire connector.

    2. Disconnect the D2 ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      D56-7 (SL) or D2-77 (S2) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. INSPECT SHIFT SOLENOID VALVE S2


    1. A01VWNRC01
      *1 Shift Solenoid Valve S2

      Remove the shift solenoid valve S2.

      Click here

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 Body 20°C (68°F) 11 to 15 Ω
    3. Connect a positive (+) lead from the battery to the terminal of the solenoid valve connector, and a negative (-) lead to the solenoid body. Check that the valve moves and makes an operating sound.

      OK
      Valve moves and makes an operating sound.
      Result
      Proceed to
      OK
      NG

    OK
    NG