| DTC Code | DTC Name |
|---|---|
| P271313 | Pressure Control Solenoid "D" Circuit Open |
DESCRIPTION
Refer to DTC P27137F.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P271313 | Pressure Control Solenoid "D" Circuit Open | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
Comes on | DTC stored | SAE Code: P2716 |
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve SLT circuit is detected, the ECM will determine that there is a malfunction, illuminate the MIL and store this DTC.
WIRING DIAGRAM
| *a | Shift Solenoid Valve SLT |
| *b | Transmission Wire |
CAUTION / NOTICE / HINT
Note
Perform registration and/or initialization when parts related to the automatic transaxle are replaced.
Tech Tips
After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Start the engine.
Check for DTCs again.
PROCEDURE
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) - ECM)
Disconnect the D2 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) Click here |
| OK |
|
REPLACE ECM
Replace the ECM.
| Result | ||
|---|---|---|
|
| NEXT |
|
PERFORM A/T CODE REGISTRATION Click here |
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
Disconnect the D56 transmission wire connector.
Disconnect the D2 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM) |
| OK |
|
INSPECT SHIFT SOLENOID VALVE SLT
| *a | Component without harness connected (Shift Solenoid Valve SLT) |
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect a positive (+) lead from the battery to terminal 1 and a negative (-) lead with a 21 W bulb to terminal 2 of the solenoid valve connector. Check that the valve moves and makes an operating sound.
| OK |
|---|
| Valve moves and makes an operating sound. |
| Result | |||
|---|---|---|---|
|
| OK |
|
REPAIR OR REPLACE TRANSMISSION WIRE Click here |
| NG |
|
REPLACE SHIFT SOLENOID VALVE SLT Click here |