PROCEDURE
INSTALL ATF TEMPERATURE SENSOR ASSEMBLY
Coat the O-ring with ATF and install it to the ATF temperature sensor assembly.
Coat the 4 bolts with ATF.
| *a | ATF Temperature Sensor Assembly Connector |
| *b | Clamp |
Install the ATF temperature sensor assembly and clamp to the transmission valve body assembly with the 4 bolts.
Tech Tips
Bolt length:
Bolt (A): 25 mm (0.984 in.)
Bolt (B): 85 mm (3.35 in.)
Engage the clamp to connect the wire harness to the transmission valve body assembly.
Connect the ATF temperature sensor assembly connector.
INSTALL VALVE BODY OIL STRAINER ASSEMBLY