CAUTION / NOTICE / HINT
The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during heated oxygen sensor removal/installation are shown below.
| Replaced Part or Performed Procedure | Necessary Procedure | Effect/Inoperative Function when Necessary Procedure not Performed | Link |
|---|---|---|---|
|
Inspection After Repair |
|
Click here w/ Canister Pump Module Click here w/o Canister Pump Module |
PROCEDURE
REMOVE FRONT FLOOR COVER LH
REMOVE FRONT NO. 3 EXHAUST PIPE SUB-ASSEMBLY
REMOVE HEATED OXYGEN SENSOR (for Bank 1)
Remove the wire harness clamp bracket from the heated oxygen sensor.
Using SST, remove the heated oxygen sensor from the front No. 3 exhaust pipe sub-assembly.
Note
If the heated oxygen sensor has been struck or dropped, replace it.
REMOVE NO. 1 EXHAUST PIPE SUPPORT BRACKET (for Lower Side)
REMOVE FRONT EXHAUST PIPE ASSEMBLY
REMOVE HEATED OXYGEN SENSOR (for Bank 2)
Using SST, remove the heated oxygen sensor from the front exhaust pipe assembly.