2GR-FKS BATTERY / CHARGING SERVICE DATA

Battery Standard voltage 12.5 to 12.9 V at 20°C (68°F)
Fuse Standard resistance Below 1 Ω
Charging circuit without load Standard amperage 10 A or higher
Standard voltage 13.2 to 14.8 V
Charging circuit with load Standard amperage 30 A or higher