| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Battery positive (+) terminal - Terminal 30 - Terminal 50 | 11.5 V | Below 90 A |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Segment - Segment | Always | Below 1 Ω |
| Segment - Starter armature core | 10 kΩ or higher |
| Commutator length | Standard Length | 3.1 mm (0.122 in.) |
| Maximum Length | 3.8 mm (0.150 in.) |
| Brush length | Standard Length | 9.0 mm (0.354 in.) |
| Minimum Length | 4.0 mm (0.157 in.) |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Positive (+) brush - Negative (-) brush | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Terminal 50 - Terminal C | Always | Below 1 Ω |
| Terminal 50 -Magnet switch body | Below 2 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (SS1) - 6 (AGND) | Not pushed | 10 kΩ or higher |
| 1 (SS2) - 6 (AGND) | ||
| 5 (SS1) - 6 (AGND) | Pushed | Below 1 Ω |
| 1 (SS2) - 6 (AGND) |
| Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 9 (SWIL) Battery negative (-) → Terminal 6 (AGND) |
Illuminates |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |