FRONT ACCELERATION SENSOR(for RHD) INSPECTION

PROCEDURE


  1. INSPECT ACCELERATION SENSOR


    1. Connect 3 1.5 V dry cell batteries in series.

    2. Connect a positive (+) lead from the batteries to terminal 3 (SGB) and a negative (-) lead to terminal 2 (SGG).

    3. A01RDSKC01
      *A for LH Side
      *B for RH Side
      *a

      Component without harness connected

      (Front Acceleration Sensor)

      B005NIZ Top
      B005LWS Bottom

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LH Side
      Tester Connection Condition Specified Condition
      1 (SGFL) - 2 (SGG) Sensor stationary Approx. 2.0 to 2.5 V
      Sensor vibrating vertically Changes between approx. 0.9 and 3.6 V
      for RH Side
      Tester Connection Condition Specified Condition
      1 (SGFR) - 2 (SGG) Sensor stationary Approx. 2.0 to 2.5 V
      Sensor vibrating vertically Changes between approx. 0.9 and 3.6 V

      Note


      • Do not apply a voltage of more than 6 V.

      • Do not drop the front acceleration sensor. If it is dropped, replace it with a new one.

      • Never place the front acceleration sensor upside down.

      Tech Tips

      When the acceleration sensor is tilted, it may output a different value.