ADAPTIVE HIGH BEAM SYSTEM TERMINALS OF ECU


  1. CHECK INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY AND MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)

    Click here

  2. CHECK HEADLIGHT CONTROL COMPUTER ASSEMBLY LH

    Click here

  3. CHECK HEADLIGHT CONTROL COMPUTER ASSEMBLY RH

    Click here

  4. CHECK HEADLIGHT LIGHT CONTROL ECU SUB-ASSEMBLY

    A01QD1YN03

    1. Measure the voltage, resistance and check for pulses according to the value(s) in the table below.

      Tech Tips

      Since the headlight light control ECU sub-assembly is connected inside the headlight assembly, the voltage, resistance and pulses cannot be checked directly. The values listed are for reference only.

      Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
      K-1(LG) - Body ground - Ground Always Below 1 Ω
      K-2(AR01) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation
      K-2(AR02) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manuallyEngine switch on (IG) and high beams operated manually Pulse generation
      K-5(FH) - K-6(FL) - LED array fan power source Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually 4.75 to 5.25 V
      K-7(FG) - K-6(FL) - LED array fan control signal Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation
      K-9(LIN) - Body ground - LIN communication Engine switch on (IG) Pulse generation
      K-10(LB) - Body ground - Power source Engine switch off Below 1 V
      Engine switch on (IG) 11 to 14 V
      K-11(AR03) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation
      K-12(AR04) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation
      K-13(AR05) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation
      K-14(AR06) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation
      K-15(AR07) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation
      K-16(AR08) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation
      K-17(AR09) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation
      K-18(AR10) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation
      K-19(AR11) - K-20(AR12) - LED array output Engine switch off Below 1 V
      Engine switch on (IG) and high beams operated manually Pulse generation