RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT WIPER RELAY


    1. A01QA32E01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 4 Battery voltage not applied between terminals 1 and 2 Below 1 Ω
      Battery voltage applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
      Battery voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the WIPER relay.

  2. INSPECT INT RELAY


    1. A01QA32E01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 4 Battery voltage not applied between terminals 1 and 2 Below 1 Ω
      Battery voltage applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
      Battery voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the INT relay.