PROCEDURE
INSPECT OUTER MIRROR LH
| *a | Component without harness connected (Outer Mirror LH) |
w/ Outer Mirror Heater:
Check the outer mirror heater.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror LH.
| *a | Component without harness connected (Outer Mirror LH) |
| *b | EC Mirror Connector |
w/ Blind Spot Monitor:
Note
Do not apply a voltage of 6 V or higher.
Check the blind spot monitor indicator.
Connect 4 dry-cell batteries (1.5 V each) in series.
Connect a positive (+) lead from the batteries to terminal 2 and a negative (-) lead to terminal 1 and check that the blind spot monitor indicator comes on.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror LH.
Check the EC mirror operation.
Note
Do not apply a voltage of 1.5 V or higher.
Connect 1.5 V dry-cell battery.
| *a | Component without harness connected (Outer Mirror LH) |
Apply 1.5 V battery voltage and check the EC mirror operation.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror LH.
INSPECT OUTER MIRROR RH
| *a | Component without harness connected (Outer Mirror RH) |
w/ Outer Mirror Heater:
Check the outer mirror heater.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror RH.
| *a | Component without harness connected (Outer Mirror RH) |
| *b | EC mirror connector |
w/ Blind Spot Monitor:
Note
Do not apply a voltage of 6 V or higher.
Check the blind spot monitor indicator.
Connect 4 dry-cell batteries (1.5 V each) in series.
Connect a positive (+) lead from the batteries to terminal 2 and a negative (-) lead to terminal 1 and check that the blind spot monitor indicator comes on.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror RH.
Check the EC mirror operation.
Note
Do not apply a voltage of 1.5 V or higher.
Connect 1.5 V dry-cell battery.
| *a | Component without harness connected (Outer Mirror RH) |
Apply 1.5 V battery voltage and check the EC mirror operation.
| OK | ||||
|---|---|---|---|---|
|
If the result is not as specified, replace the outer mirror RH.