AIR CONDITIONING PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL AIR CONDITIONER PRESSURE SENSOR


    1. Remove the vinyl tape from the liquid pipe sub-assembly and the connecting part of the air conditioner pressure sensor.

    2. Sufficiently apply compressor oil to a new O-ring and fitting surface of the air conditioner pressure sensor.

      Compressor Oil
      for HFC-134a (R134a)
      ND-OIL 8 or equivalent
      for HFO-1234yf (R1234yf)
      ND-OIL 12 or equivalent

      Note

      Keep the O-rings and O-ring fitting surfaces free of foreign matter.

    3. A01Q9PXC01
      *a Turn
      *b Hold

      Using a 27 mm deep socket wrench, install the air conditioner pressure sensor as shown in the illustration.

      Torque:
      10.8 N*m  { 110 kgf*cm, 8 ft.*lbf }
    4. Connect the connector.

  2. INSTALL LOW PITCHED HORN ASSEMBLY

    Click here

  3. INSTALL FRONT BUMPER ASSEMBLY

    Click here

  4. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT

    Click here

  5. WARM UP ENGINE

    Click here

  6. INSPECT FOR REFRIGERANT LEAK

    Click here