BLOWER UNIT REASSEMBLY

PROCEDURE


  1. INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY


    1. A01QAT2

      Install the No. 1 blower damper servo sub-assembly with the 2 screws.

    2. A01QD8JC01
      *a Reference Point

      Using the reference points, engage the 3 claws to install the plate.

    3. A01QC6M

      Engage the claws to install the upper blower case.

    4. Install the 3 screws.

  2. INSTALL DRAIN COOLER HOSE


    1. A01QBZPC01
      *a Hose Notch
      *b Blower Case Assembly Rib

      Align the hose notch with the blower case assembly rib as shown in the illustration and install the drain cooler hose.

  3. INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY


    1. When reusing the blower motor with fan sub-assembly:


      1. Install a new heater packing to the blower motor with fan sub-assembly.

        Tech Tips

        For details, refer to the instruction manual provided with the part.

    2. A01QB81

      Install the blower motor with fan sub-assembly with the 3 screws.

      Note

      Do not install the blower motor with fan sub-assembly if it has been dropped or subjected to a severe impact.

  4. INSTALL CLEAN AIR FILTER


    1. A01QBNT

      Engage the guides to install the clean air filter to the cover plate as shown in the illustration.

    2. A01Q8V3C01
      B002C8N Install in this Direction

      Engage the claws to install the air filter sub-assembly as shown in the illustration.