PROCEDURE
PRECAUTION
Note
Make sure to perform initialization after replacing the No. 1 blower damper servo sub-assembly. If initialization is not performed, the air conditioning unit assembly will not perform properly as the air conditioning amplifier assembly will not be able to recognize the position of the No. 1 blower damper servo sub-assembly.
REMOVE CLEAN AIR FILTER
|
Remove in this Direction |
Disengage the claws to remove the air filter sub-assembly as shown in the illustration.
Disengage the guides to remove the clean air filter from the cover plate.
REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY
Remove the 3 screws and blower motor with fan sub-assembly.
When reusing the blower motor with fan sub-assembly:
Remove the heater packing from the blower motor with fan sub-assembly.
REMOVE DRAIN COOLER HOSE
Remove the drain cooler hose.
REMOVE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
Remove the 3 screws.
Disengage the claws to remove the upper blower case.
Disengage the claws to remove the plate.
Remove the 2 screws and No. 1 blower damper servo sub-assembly.