AIR CONDITIONING SYSTEM, Diagnostic DTC:B1411/11

DTC Code DTC Name
B1411/11 Room Temperature Sensor Circuit

DESCRIPTION

The cooler thermistor (room temperature sensor) is installed in the instrument panel to detect the cabin temperature which is used to control the heater and air conditioning system AUTO mode. The resistance of the cooler thermistor (room temperature sensor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (room temperature sensor) and reads voltage changes due to changes in the resistance of the cooler thermistor (room temperature sensor).

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1411/11 Room Temperature Sensor Circuit

Any of the following conditions is met:


  • Open in cooler thermistor (room temperature sensor) circuit

  • Short in cooler thermistor (room temperature sensor) circuit


  • Cooler thermistor (room temperature sensor)

  • Harness or connector

  • Air conditioning amplifier assembly

Memorized (4 seconds or more)

Tech Tips


  • The air conditioning amplifier assembly stores the DTC of the respective malfunction if it has occurred for the period of time indicated in the brackets.

  • If the cabin temperature is approximately -18.6°C (-1.48°F) or less, DTC B1411/11 may be output even though the system is normal.

DTC Detection Conditions
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition Engine switch to on (IG)
Malfunction Status Open in cooler thermistor (room temperature sensor) circuit -
Short in cooler thermistor (room temperature sensor) circuit -
Detection Time 4 seconds or more 4 seconds or more
Number of Trips 1 trip 1 trip

Tech Tips

DTC will be output when conditions for either of the patterns in the table above are met.

WIRING DIAGRAM

A01Q97CE05
*a Cooler Thermistor (Room Temperature Sensor)
*b Air Conditioning Amplifier Assembly

CAUTION / NOTICE / HINT

Note

Before disconnecting the cable from the negative (-) battery terminal or replacing the air conditioning amplifier assembly, record the last operation state of the air conditioning for each transmitter. After replacement, it is necessary to perform memory registration for each transmitter.

Click here

PROCEDURE


  1. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch to on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.


      Body Electrical > Air Conditioner > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Room Temperature Sensor Cooler thermistor (room temperature sensor)

      Min.: -6.50°C (-20.30°F)

      Max.: 57.25°C (135.05°F)

      Actual ambient temperature displayed -

      Body Electrical > Air Conditioner > Data List
      Tester Display
      Room Temperature Sensor
      OK
      The display is as specified in the normal condition column.
      Result
      Result Proceed to
      OK (When troubleshooting according to Problem Symptoms Table) A
      OK (When troubleshooting according to the DTC) B
      NG C

    A
    B
    C
  2. INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)


    1. Remove the cooler thermistor (room temperature sensor).

      Click here

    2. Inspect the cooler thermistor (room temperature sensor).

      Click here

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - COOLER THERMISTOR [ROOM TEMPERATURE SENSOR])


    1. Disconnect the K65 air conditioning amplifier assembly connector.

    2. Disconnect the K36 cooler thermistor (room temperature sensor) connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      K65-16 (TR) - K36-1 (+) Always Below 1 Ω
      K65-1 (SG-1) - K36-2 (-) Always Below 1 Ω
      K65-16 (TR) or K36-1 (+) - Body ground Always 10 kΩ or higher
      K65-1 (SG-1) or K36-2 (-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    OK
    NG