PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE PIPING CLAMP
| *1 | Liquid Pipe Sub-assembly |
Install SST to the piping clamp as shown in the illustration.
|
Push in |
Hold the liquid pipe sub-assembly with each hand and push in SST with both thumbs.
Note
Do not apply excessive force to the liquid pipe sub-assembly as they may bend.
| *1 | Liquid Pipe Sub-assembly |
|
Stopper |
|
Pull off |
Raise the stopper of SST and remove SST and piping clamp together.
Remove the piping clamp from SST.
Remove the liquid pipe sub-assembly.
Remove the 2 O-rings from the liquid pipe sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.