DESCRIPTION
When the theft deterrent system is switched from the armed state to the alarm sounding state, the main body ECU (multiplex network body ECU) transmits a signal to cause the horns to sound at intervals of 0.4 seconds.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
If the main body ECU (multiplex network body ECU) is replaced, refer to Service Bulletin.
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
CHECK HORNS
Press the horn switch and check if the horns sound.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| B |
|
GO TO HORN SYSTEM Click here |
| A |
|
INSPECT COWL SIDE JUNCTION BLOCK LH
Remove the main body ECU (multiplex network body ECU).
| *a | Component without harness connected (Cowl Side Junction Block LH) |
- | - |
Disconnect the cowl side junction block LH connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| OK |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) Click here |
| NG |
|
REPLACE COWL SIDE JUNCTION BLOCK LH Click here |