INTEGRATION RELAY INSPECTION

PROCEDURE


  1. INSPECT NO. 1 INTEGRATION RELAY


    1. B002E4PC09
      *a

      Component without harness connected

      (No. 1 Integration Relay)

      IG2 RELAY


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition

        2D-1 - 2E-2

        2D-1 - 2F-6

        2D-1 - 2F-7

        2D-1 - 2F-8

        Battery voltage not applied between terminals

        2E-5 - 2E-4

        10 kΩ or higher

        Battery positive (+) → 2E-5

        Battery negative (-) → 2E-4

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-5 - 2E-16

        10 kΩ or higher

        Battery positive (+) → 2E-5

        Battery negative (-) → 2E-16

        Below 1 Ω
    2. B002E4PC09
      *a

      Component without harness connected

      (No. 1 Integration Relay)

      INJ2 RELAY


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition

        2D-1 - 2F-11

        2D-1 - 2F-12

        Battery voltage not applied between terminals

        2E-8 - 2E-4

        and

        2D-1 - 2E-19

        10 kΩ or higher

        Battery positive (+) → 2E-8

        Battery negative (-) → 2E-4

        and

        Battery positive (+) → 2D-1

        Battery negative (-) → 2E-19

        Below 1Ω

        Battery voltage not applied between terminals

        2E-9 - 2E-4

        and

        2D-1 - 2E-19

        10 kΩ or higher

        Battery positive (+) → 2E-9

        Battery negative (-) → 2E-4

        and

        Battery positive (+) → 2D-1

        Battery negative (-) → 2E-19

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-8 - 2E-16

        and

        2D-1 - 2E-19

        10 kΩ or higher

        Battery positive (+) → 2E-8

        Battery negative (-) → 2E-16

        and

        Battery positive (+) → 2D-1

        Battery negative (-) → 2E-19

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-9 - 2E-16

        and

        2D-1 - 2E-19

        10 kΩ or higher

        Battery positive (+) → 2E-9

        Battery negative (-) → 2E-16

        and

        Battery positive (+) → 2D-1

        Battery negative (-) → 2E-19

        Below 1 Ω
    3. B002E4PC09
      *a

      Component without harness connected

      (No. 1 Integration Relay)

      INJ1 RELAY


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition

        2D-1 - 2F-4

        2D-1 - 2F-5

        Battery voltage not applied between terminals

        2E-8 - 2E-4

        and

        2D-1 - 2E-19

        10 kΩ or higher

        Battery positive (+) → 2E-8

        Battery negative (-) → 2E-4

        and

        Battery positive (+) → 2D-1

        Battery negative (-) → 2E-19

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-9 - 2E-4

        and

        2D-1 - 2E-19

        10 kΩ or higher

        Battery positive (+) → 2E-9

        Battery negative (-) → 2E-4

        and

        Battery positive (+) → 2D-1

        Battery negative (-) → 2E-19

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-8 - 2E-16

        and

        2D-1 - 2E-19

        10 kΩ or higher

        Battery positive (+) → 2E-8

        Battery negative (-) → 2E-16

        and

        Battery positive (+) → 2D-1

        Battery negative (-) → 2E-19

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-9 - 2E-16

        and

        2D-1 - 2E-19

        10 kΩ or higher

        Battery positive (+) → 2E-9

        Battery negative (-) → 2E-16

        and

        Battery positive (+) → 2D-1

        Battery negative (-) → 2E-19

        Below 1 Ω
    4. B002E4PC09
      *a

      Component without harness connected

      (No. 1 Integration Relay)

      EFI MAIN1 RELAY


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition

        2D-1 - 2E-3

        2D-1 - 2E-4

        2D-1 - 2E-13

        2D-1 - 2E-14

        2D-1 - 2E-15

        2D-1 - 2E-16

        2D-1 - 2E-19

        Battery voltage not applied between terminals

        2E-8 - 2E-4

        10 kΩ or higher

        Battery positive (+) → 2E-8

        Battery negative (-) → 2E-4

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-9 - 2E-4

        10 kΩ or higher

        Battery positive (+) → 2E-9

        Battery negative (-) → 2E-4

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-8 - 2E-16

        10 kΩ or higher

        Battery positive (+) → 2E-8

        Battery negative (-) → 2E-16

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-9 - 2E-16

        10 kΩ or higher

        Battery positive (+) → 2E-9

        Battery negative (-) → 2E-16

        Below 1 Ω
    5. B002E4PC09
      *a

      Component without harness connected

      (No. 1 Integration Relay)

      A/F RELAY


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        2D-1 - 2F-10

        Battery voltage not applied between terminals

        2E-8 - 2E-4

        10 kΩ or higher

        Battery positive (+) → 2E-8

        Battery negative (-) → 2E-4

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-9 - 2E-4

        10 kΩ or higher

        Battery positive (+) → 2E-9

        Battery negative (-) → 2E-4

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-8 - 2E-16

        10 kΩ or higher

        Battery positive (+) → 2E-8

        Battery negative (-) → 2E-16

        Below 1 Ω

        Battery voltage not applied between terminals

        2E-9 - 2E-16

        10 kΩ or higher

        Battery positive (+) → 2E-9

        Battery negative (-) → 2E-16

        Below 1 Ω

        Battery voltage not applied between terminals

        2D-1 - 2E-4

        10 kΩ or higher

        Battery positive (+) → 2D-1

        Battery negative (-) → 2E-4

        Below 1 Ω

        Battery voltage not applied between terminals

        2D-1 - 2E-16

        10 kΩ or higher

        Battery positive (+) → 2D-1

        Battery negative (-) → 2E-16

        Below 1 Ω