BLIND SPOT MONITOR SYSTEM, Diagnostic DTC:U0232

DTC Code DTC Name
U0232 Lost Communication with Blind Spot Monitor Slave Module

DESCRIPTION

This DTC is stored when the blind spot monitor sensor LH judges that there is a communication problem with the blind spot monitor sensor RH.

DTC No. Detection Item DTC Detection Condition Trouble Area
U0232 Lost Communication with Blind Spot Monitor Slave Module The blind spot monitor sensor (master) cannot receive signals from the blind spot monitor sensor (slave)
  • CAN communication line

  • Blind spot monitor sensor LH

  • Blind spot monitor sensor RH

WIRING DIAGRAM

A01QD1JE61
*a from RR-IG1 RLY1 Relay
*b Blind Spot Monitor Sensor LH
*c Blind Spot Monitor Sensor RH
*d CAN Communication Line

CAUTION / NOTICE / HINT

Note


  • When checking for DTCs, make sure that the blind spot monitor system is turned on.

  • Inspect the fuses for circuits related to this system before performing the following procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BLIND SPOT MONITOR SENSOR RH)


    1. Disconnect the U37 blind spot monitor sensor LH connector.

    2. Disconnect the T31 blind spot monitor sensor RH connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      U37-1 (CA2P) - T31-1 (CA2P) Always Below 1 Ω
      U37-6 (CA2N) - T31-6 (CA2N) Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH POWER SOURCE TERMINAL)


    1. A01QCKBN01

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      U37-5 (BLB) - Body ground Engine switch on (IG) 11 to 14 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH GROUND TERMINAL)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      U37-10 (BLGD) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. REPLACE BLIND SPOT MONITOR SENSOR LH


    1. Replace the blind spot monitor sensor LH.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  5. RECHECK DTC


    1. Clear the DTCs.

      Click here


      Body Electrical > Blind Spot Monitor Master > Clear DTCs
    2. Recheck for DTCs and check if the same DTC is output again.


      Body Electrical > Blind Spot Monitor Master > Trouble Codes
      OK
      No DTCs are output.
      Result
      Proceed to
      OK
      NG

    OK
    NG