AIR CLEANER FILTER ELEMENT REMOVAL

PROCEDURE


  1. DISCONNECT VENTILATION HOSE


    1. A01Q8K3C01
      *1 No. 2 Ventilation Hose
      *2 No. 3 Ventilation Hose

      Slide the 2 clips and disconnect the No. 2 ventilation hose and No. 3 ventilation hose from the air cleaner hose assembly.

  2. SEPARATE AIR CLEANER CAP WITH AIR CLEANER HOSE


    1. A01QAG7

      Disconnect the 2 clamp hooks from the air cleaner cap sub-assembly.

    2. A01QCDH

      Loosen the clamp and disconnect the air cleaner hose assembly from the throttle body with motor assembly.

    3. Disengage the 2 guides and separate the air cleaner cap with air cleaner hose from the air cleaner case sub-assembly.

  3. REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY


    1. A01Q9PU

      Remove the air cleaner filter element sub-assembly from the air cleaner case sub-assembly.

      Note

      Do not allow foreign matter to enter the air cleaner case sub-assembly.

  4. INSPECT AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

    Tech Tips

    This procedure is only performed when the air cleaner filter element sub-assembly will be reused.


    1. Check whether the air cleaner filter element sub-assembly is dirty or clogged.

    2. A01QB49C01
      *a Air Cleaner Filter Element Sub-assembly Intake Downstream Side

      If the air cleaner filter element sub-assembly is dirty or has foreign matter adhered to it, clean the air cleaner filter element sub-assembly with compressed air.

      Note

      When cleaning the air cleaner filter element sub-assembly, blow the compressed air from the intake downstream side.

      Tech Tips

      If the air cleaner filter element sub-assembly is still extremely dirty after cleaning it, replace the air cleaner filter element sub-assembly with a new one.