2UR-GSE BATTERY / CHARGING SERVICE DATA

Battery Standard specific gravity 1.25 more at 20°C (68°F)
Standard voltage 12.3 more at 20°C (68°F)
Fuse Standard resistance Below 1 Ω
Charging circuit without load Standard current 10 A or higher
Standard voltage 13.2 to 14.8 V
Charging circuit with load Standard current 30 A or higher
Generator Brush Holder Assembly
Brush length Standard exposed brush length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed brush length 4.5 mm (0.177 in.)
Generator Rotor Assembly
Tester Connection Condition Specified Condition
Slip ring - Slip ring Approx. 20°C (68°F) 1.36 to 1.76 Ω
Slip ring - Rotor Always 10 MΩ or higher
Slip ring diameter Standard diameter 14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum diameter 14.0 mm (0.551 in.)