PROCEDURE
INSPECT PURGE VALVE (PURGE VSV)
| *a | Component without harness connected (Purge Valve (Purge VSV)) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the purge valve (purge VSV).
| *a | Port (E) |
| *b | Port (F) |
| *c | Air |
| *d | Component without harness connected (Purge Valve (Purge VSV)) |
Apply battery voltage between the terminals of the purge valve (purge VSV) and check that the following occurs when blowing air into the port (E).
| OK | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the purge valve (purge VSV).