CAUTION / NOTICE / HINT
Note
Do not apply positive (+) auxiliary battery voltage to any terminals, except terminal 2 (B), to avoid damaging the pulse sensor inside the motor.
Perform initialization of the power window system after removing, inspecting or replacing the power window regulator motor assembly.
PROCEDURE
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
| *a | Component without harness connected (Power Window Regulator Motor Assembly LH) |
| *b | Clockwise |
| *c | Counterclockwise |
| *d | Motor Gear |
Connect a positive (+) auxiliary battery lead to connector terminal 2 (B).
Note
Do not connect a positive (+) auxiliary battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a negative (-) auxiliary battery lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| OK | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the power window regulator motor assembly LH.
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
| *a | Component without harness connected (Power Window Regulator Motor Assembly RH) |
| *b | Clockwise |
| *c | Counterclockwise |
| *d | Motor Gear |
Connect a positive (+) auxiliary battery lead to connector terminal 2 (B).
Note
Do not connect a positive (+) auxiliary battery lead to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
Connect a negative (-) auxiliary battery lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows:
| OK | ||||||
|---|---|---|---|---|---|---|
|
If the result is not as specified, replace the power window regulator motor assembly RH.