CHARGING SYSTEM PRECAUTION
CAUTION:
This vehicle has contains high voltage circuits standardized with orange colored wiring and connectors, so follow the instructions in this manual to perform the procedures correctly.
If the correct procedures are not followed according to the instructions in this manual, there is a danger of electric shock from the high voltage circuits.
Be sure to wear insulating gloves when working on high voltage wiring or components.
If work is performed without wearing insulating gloves, there is a danger of electric shock.
Note
If the auxiliary battery is fully depleted or the READY indicator does not illuminate, recharge the auxiliary battery.
Never disconnect the auxiliary battery while the power switch is on (READY).
Before giving the auxiliary battery a quick charge, disconnect the auxiliary battery cables.
Check the auxiliary battery again before the vehicle is returned to the customer.
When replacing the auxiliary battery, use a new auxiliary battery of the same dimensions with a capacity of 51 Ah or more at a 20-hour rate.