VSC OFF SWITCH INSPECTION

PROCEDURE


  1. INSPECT VSC OFF SWITCH (ELECTRIC PARKING BRAKE SWITCH ASSEMBLY) (for LHD)


    1. Check the resistance.


      1. A005NUBC02
        *a

        Component without harness connected

        (VSC OFF Switch (Electric Parking Brake Switch Assembly))

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        13 (+) - 8 (E) Switch pushed Below 1 Ω
        13 (+) - 8 (E) Switch not pushed 10 kΩ or higher

        If the result is not as specified, replace the VSC OFF switch (electric parking brake switch assembly).

  2. INSPECT VSC OFF SWITCH (ELECTRIC PARKING BRAKE SWITCH ASSEMBLY) (for RHD)


    1. Check the resistance.


      1. A001PHMC05
        *a

        Component without harness connected

        (VSC OFF Switch (Electric Parking Brake Switch Assembly))

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        11 (+) - 8 (E) Switch pushed Below 1 Ω
        11 (+) - 8 (E) Switch not pushed 10 kΩ or higher

        If the result is not as specified, replace the VSC OFF switch (electric parking brake switch assembly).