FLOW SHUTTING VALVE REMOVAL

CAUTION / NOTICE / HINT

The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during shutting valve (water valve) removal/installation are shown below.

Necessary Procedure After Parts Removed/Installed/Replaced
Replaced Part or Performed Procedure Necessary Procedure Effect/Inoperative Function when Necessary Procedure not Performed Link
Auxiliary battery terminal is disconnected/reconnected Memorize steering angle neutral point Lane departure alert system (w/ Steering Control System)

Click here

Simple intelligent parking assist system*1
Toyota parking assist-sensor system*1
Pre-collision system
Initialize back door lock Power door lock control system

Click here

Replacement of inverter with converter assembly Resolver learning
  • DTCs are stored

  • Slight vibration at a vehicle speed of 5 km/h (3 mph) or less

  • Shock or vibration during acceleration

Click here


    for SFI system

  • Replacement of ECM

Perform Vehicle Identification Number (VIN) registration MIL comes on

Click here

*1: When performing learning using the GTS.
Click here Click here

PROCEDURE


  1. REMOVE NO. 1 ENGINE UNDER COVER

    Click here

  2. REMOVE INVERTER WITH CONVERTER ASSEMBLY

    Click here

  3. DRAIN ENGINE COOLANT (for Engine)

    Click here

  4. REMOVE FLOW SHUTTING VALVE (WATER VALVE)

    A005MTU

    1. Disconnect the 3 connectors.

    2. Disengage the clamp to disconnect the wire harness from the water outlet.

    3. A005NLP

      Slide the clip and disconnect the No. 3 radiator hose.

    4. A005O36

      Slide the clip and disconnect the No. 9 water by-pass hose.

    5. A005ND2

      Remove the 2 nuts.

    6. Slide the clip and disconnect the No. 10 water by-pass hose and remove the water outlet with the flow shutting valve (water valve).

    7. Remove the water outlet gasket from the cylinder head sub-assembly.

    8. Secure the water outlet in a vise between aluminum plates.

      Note

      Do not damage the water outlet.

    9. A005O7T

      Remove the 2 bolts and flow shutting valve (water valve).

    10. A005MTH

      Remove the gasket from the flow shutting valve (water valve).