| DTC Code | DTC Name |
|---|---|
| P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:
Internal inverter malfunction
Current sensor malfunction
Inverter with converter assembly internal circuit malfunction
DESCRIPTION
The motor generator control ECU (MG ECU), which is built into the inverter with converter assembly, monitors the generator inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | Generator inverter current sensor U phase offset malfunction: The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the generator inverter is shutdown (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
| P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | Generator inverter current sensor V phase offset malfunction: The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the generator inverter is shutdown (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
| P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | Generator inverter current sensor W phase offset malfunction: The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the generator inverter is shutdown (1 trip detection logic) |
|
Comes on | Master Warning Light: Comes on |
CONFIRMATION DRIVING PATTERN
Tech Tips
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
With power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY) with park (P) selected and wait for 5 seconds or more.
Move the shift lever to N and wait for 5 seconds or more.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
Tech Tips
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
CAUTION / NOTICE / HINT
CAUTION:
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
PROCEDURE
CHECK DTC OUTPUT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
Check for DTCs.
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System (A/C Area) Insulation Resistance Decreased |
| P1C7D49 | Hybrid/EV Battery Voltage System (Hybrid/EV Battery Area) Insulation Resistance Decreased | ||
| P1C7E49 | Hybrid/EV Battery Voltage System (Transaxle Area) Insulation Resistance Decreased | ||
| P1C7F49 | Hybrid/EV Battery Voltage System (Direct Current Area) Insulation Resistance Decreased | ||
| High voltage circuit malfunction | Hybrid control system | P0AA649 | Hybrid/EV Battery Voltage System Insulation Resistance Decreased |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Motor generator control system | P0A1A47 | Generator Control Module Watchdog / Safety μC Failure |
| P0A1A49 | Generator Control Module Internal Electronic Failure | ||
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
| P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
| P312487 | Lost Communication between Drive Motor "A" and HV ECU Missing Message | ||
| P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
| P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
| P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
| Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | |
| Power source circuit malfunction | Motor generator control system | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
| Sensor and actuator circuit malfunction | Motor generator control system | P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold |
| P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | ||
| P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | ||
| P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | ||
| P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | ||
| P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | ||
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
| P1CAC49 | Generator Position Sensor Internal Electronic Failure | ||
| P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
| System malfunction | Motor generator control system | P0A7A73 | Generator Inverter Actuator Stuck Closed |
Tech Tips
P0E0028, P0E0428 and P0E0828 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Turn the power switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| C |
|
GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connection condition of the low voltage connectors of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and the connector for water and foreign matter.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the claws of the lock levers are engaged and that the connector cannot be pulled off.
| OK |
|---|
| - The connector is connected securely. |
| - The terminals are not deformed and are connected securely. |
| - No water or foreign matter in the connector. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Tech Tips
When connecting the connector, connect it with the lock levers raised. Rotate each lock lever downward and make sure that the connector is securely connected. When a lock lever is fully lowered, a click will be heard as its claw engages. After the click is heard, pull up on the connector to confirm that it is securely connected.
| A |
|
REPLACE INVERTER WITH CONVERTER ASSEMBLY Click here |
| B |
|
CONNECT SECURELY |
| C |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |