HYBRID CONTROL SYSTEM, Diagnostic DTC:P0AE415

Info Added 2017-10-06

DTC Code DTC Name
P0AE415 Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open

DESCRIPTION

Refer to the description for DTC P0AE411.

Click here

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0AE415 Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open

Open or short to +B in SMRP circuit:

Primary circuit of SMRP is malfunctioning.

(2 trip detection logic)


  • Wire harness or connector

  • HV battery junction block assembly

  • Hybrid vehicle control ECU

Does not come on

Master Warning Light:

Comes on

Related Data List
DTC No. Data List
P0AE415
  • VL-Voltage before Boosting

  • VH-Voltage after Boosting

  • Hybrid Battery Voltage

  • SMRP Status

  • SMRB Status

  • SMRG Status

  • SMRP Control Status

  • SMRB Control Status

  • SMRG Control Status

  • Boosting Converter Shutdown Status

  • Generator Inverter Shutdown Status

  • Motor Inverter Shutdown Status

CONFIRMATION DRIVING PATTERN

Tech Tips

After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click here


  1. Connect the GTS to the DLC3.

  2. Turn the power switch on (IG) and turn the GTS on.

  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

  4. Turn the power switch off and wait for 2 minutes or more.

  5. Turn the power switch on (READY) and wait for 30 seconds or more.

  6. Turn the power switch off and wait for 60 seconds or more.

  7. Turn the power switch on (IG) and turn the GTS on.

  8. Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

  9. Check the DTC judgment result.

    Tech Tips


    • If the judgment result shows NORMAL, the system is normal.

    • If the judgment result shows ABNORMAL, the system has a malfunction.

    • If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.

WIRING DIAGRAM

Refer to the wiring diagram for the HV battery high-voltage line circuit.

Click here

CAUTION / NOTICE / HINT

CAUTION:


  • B0048QQ

    Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.


    • Inspecting the high-voltage system

    • Disconnecting the low voltage connector of the inverter with converter assembly

    • Disconnecting the low voltage connector of the HV battery


  • A005NJP

    To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.


  • A005NAH

    After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.


  • B0048M5C01
    *a Without waiting for 10 minutes

    After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    Click here

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click here

Tech Tips

If DTC P0AE415 is output, the power switch cannot be turned on (READY).

PROCEDURE


  1. READ VALUE USING GTS (SMRP STATUS)


    1. Connect the GTS to the DLC3

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Data List / SMRP Status.


      Powertrain > Hybrid Control > Data List
      Tester Display
      SMRP Status
    4. Read the Data List.

      Standard
      Tester Display Condition Specified Condition
      SMRP Status Power switch on (IG) OFF
    5. Turn the power switch off.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)

    Result
    Proceed to
    OK
    NG

    1. Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU connectors.

      Click here

      A005N5YC01
      *A for LHD *B for RHD
      OK
      The connectors are connected securely and there are no contact pressure problems.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK CONNECTOR CONNECTION CONDITION (FLOOR WIRE CONNECTOR)

    Result
    Result Proceed to
    OK A
    NG (The connector is not connected securely.) B
    NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

    1. A005NE7C01
      *A for LHD
      *B for RHD

      Check the connection condition of the MF2 or MF1 floor wire connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.

      Click here

      OK
      - The connector is connected securely.
      - The terminals are not deformed and are connected securely.
      - No water or foreign matter in the connector.
      Result
      Result Proceed to
      OK A
      NG (The connector is not connected securely.) B
      NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

    B
    C
    A
  4. CHECK CONNECTOR CONNECTION CONDITION (HV BATTERY JUNCTION BLOCK ASSEMBLY CONNECTOR)

    Result
    Proceed to
    OK
    NG

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 1 HV battery cover panel RH.

      Click here

    3. A005MLBN04

      Check the connector connections and contact pressure of the relevant terminals of the M42 HV battery junction block assembly connector.

      Click here

      OK
      The connectors are connected securely and there are no contact pressure problems.
    4. Install the No. 1 HV battery cover panel RH.

      Result
      Proceed to
      OK
      NG

    OK
    NG
  5. CHECK HARNESS AND CONNECTOR (SMRP VOLTAGE)


    1. Turn the power switch on (IG).

    2. A005NZLC08
      *a

      Component with harness connected

      (Hybrid Vehicle Control ECU)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      F2-3 (SMRP) - Body ground Power switch on (IG) Below 1 V
    3. Turn the power switch off.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  6. CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)

    Result
    Proceed to
    OK
    NG

    1. Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU connectors.

      Click here

      A005N5YC01
      *A for LHD *B for RHD
      OK
      The connectors are connected securely and there are no contact pressure problems.
      Result
      Proceed to
      OK
      NG

    OK
    NG
  7. CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - BODY GROUND)


    1. Disconnect the hybrid vehicle control ECU connector.

    2. A005MRDC04
      *a

      Rear view of wire harness connector

      (to Hybrid Vehicle Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F2-3 (SMRP) - Body ground Power switch off 140 to 290 Ω
    3. Reconnect the hybrid vehicle control ECU connector.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  8. CHECK HARNESS AND CONNECTOR (SHORT TO POWER SUPPLY WIRES)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 1 HV battery cover panel RH.

      Click here

    3. A005MLBN04

      Disconnect the HV battery junction block assembly connector.

    4. Disconnect the hybrid vehicle control ECU connector.

    5. Turn the power switch on (IG).

    6. A005NMIC05
      *a

      Rear view of wire harness connector

      (to Hybrid Vehicle Control ECU)

      *b

      Rear view of wire harness connector

      (to HV Battery Junction Block Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      F2-3 (SMRP) and M42-2 (SMRP) - Body ground and other terminals Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the hybrid vehicle control ECU connector and the HV battery junction block assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    7. Turn the power switch off.

    8. Reconnect the hybrid vehicle control ECU connector.

    9. Reconnect the HV battery junction block assembly connector.

    10. Install the No. 1 HV battery cover panel RH.

      Result
      Proceed to
      OK
      NG

    OK
    NG
  9. CHECK CONNECTOR CONNECTION CONDITION (FLOOR WIRE CONNECTOR)

    Result
    Result Proceed to
    OK A
    NG (The connector is not connected securely.) B
    NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

    1. A005NE7C01
      *A for LHD
      *B for RHD

      Check the connection condition of the MF2 or MF1 floor wire connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.

      Click here

      OK
      - The connector is connected securely.
      - The terminals are not deformed and are connected securely.
      - No water or foreign matter in the connector.
      Result
      Result Proceed to
      OK A
      NG (The connector is not connected securely.) B
      NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

    B
    C
    A
  10. CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - HV BATTERY JUNCTION BLOCK ASSEMBLY)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 1 HV battery cover panel RH.

      Click here

    3. A005MLBN04

      Disconnect the HV battery junction block assembly connector.

    4. Disconnect the hybrid vehicle control ECU connector.

    5. A005NMIC05
      *a

      Rear view of wire harness connector

      (to Hybrid Vehicle Control ECU)

      *b

      Rear view of wire harness connector

      (to HV Battery Junction Block Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      F2-3 (SMRP) - M42-2 (SMRP) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      F2-3 (SMRP) and M42-2 (SMRP) - Body ground and other terminals Power switch off 10 kΩ or higher
    6. Reconnect the hybrid vehicle control ECU connector.

    7. Reconnect the HV battery junction block assembly connector.

    8. Install the No. 1 HV battery cover panel RH.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  11. CHECK HARNESS AND CONNECTOR (HV BATTERY JUNCTION BLOCK ASSEMBLY - BODY GROUND)

    Result
    Proceed to
    OK
    NG

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 1 HV battery cover panel RH.

      Click here

    3. Disconnect the HV battery junction block assembly connector.

    4. A005N8BC01
      *a

      Rear view of wire harness connector

      (to HV Battery Junction Block Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      M42-3 (GND) - Body ground Power switch off Below 1 Ω
    5. Reconnect the HV battery junction block assembly connector.

    6. Install the No. 1 HV battery cover panel RH.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  12. INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRP)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the No. 1 HV battery cover panel RH.

      Click here

    3. Disconnect the HV battery junction block assembly connector.

    4. Measure the resistance according to the value(s) in the table below.

      A005MWDC63
      *a

      Component without harness connected

      (HV Battery Junction Block Assembly)

      - -
      Standard Resistance
      Tester Connection Condition Specified Condition
      M42-2 (SMRP) - M42-3 (GND) -40 to 80°C (-40 to 176°F) 140 to 290 Ω
    5. Reconnect the HV battery junction block assembly connector.

    6. Install the No. 1 HV battery cover panel RH.

      Result
      Proceed to
      OK
      NG

    OK
    NG