VALVE BODY ASSEMBLY INSPECTION

PROCEDURE


  1. INSPECT SHIFT SOLENOID VALVE SL


    1. A01W4UFE03
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SL)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Solenoid Connector - Solenoid Body 20°C (68°F) 11 to 15 Ω

      • If the result is not as specified, replace the shift solenoid valve SL.

    2. Connect a positive (+) lead from the battery to the terminal of the shift solenoid valve SL connector and a negative (-) lead to the shift solenoid valve SL body, and check the operation of the valve.

      Note

      When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

      OK
      The valve moves and makes an operating sound.

      • If the result is not as specified, replace the shift solenoid valve SL.

  2. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01W2VBE47
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SLT)

      *b 21 W Bulb

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω

      If the result is not as specified, replace the shift solenoid valve SLT.

    2. Connect a positive (+) lead with a 21 W bulb from the battery to terminal 2 and a negative (-) lead to terminal 1 of the shift solenoid valve SLT connector and check the operation of the valve.

      Note

      When using battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.

      OK
      The valve moves and makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve SLT.

  3. INSPECT SHIFT SOLENOID VALVE SLU

    Tech Tips

    Use the same procedure as for the shift solenoid valve SLT.

  4. INSPECT SHIFT SOLENOID VALVE SL1

    Tech Tips

    Use the same procedure as for the shift solenoid valve SLT.

  5. INSPECT SHIFT SOLENOID VALVE SL2

    Tech Tips

    Use the same procedure as for the shift solenoid valve SLT.

  6. INSPECT SHIFT SOLENOID VALVE SL3

    Tech Tips

    Use the same procedure as for the shift solenoid valve SLT.

  7. INSPECT SHIFT SOLENOID VALVE SL4

    Tech Tips

    Use the same procedure as for the shift solenoid valve SLT.