DESCRIPTION
Refer to the system description for DTC P2714 Click here.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2716 | Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic). |
|
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.
WIRING DIAGRAM
| *1 | Shift Solenoid Valve SLT |
| *2 | Transaxle Assembly |
PROCEDURE
INSPECT TRANSMISSION WIRE (SLT)
| *a | Component without harness connected (Transmission Wire) |
Remove the TCM from the transaxle.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| OK |
|
REPLACE TCM Click here |
| NG |
|
INSPECT SHIFT SOLENOID VALVE SLT
| *1 | Shift Solenoid Valve SLT |
Remove shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.
| OK |
|---|
| Valve moves and makes an operating sound. |
| OK |
|
REPLACE TRANSMISSION WIRE Click here |
| NG |
|
REPLACE SHIFT SOLENOID VALVE SLT Click here |