AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P2759

DTC Code DTC Name
P2759 Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU)

DESCRIPTION

Refer to the system description for DTC P2757 Click here.

DTC No. DTC Detection Condition Trouble Area
P2759 Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1-trip detection logic).
  • Open or short in shift solenoid valve SLU circuit

  • Shift solenoid valve SLU

  • TCM

MONITOR DESCRIPTION

When an open or short in a shift solenoid valve (SLU) circuit is detected, the TCM determines there is a malfunction. The TCM will turn on the MIL and store this DTC.

WIRING DIAGRAM

A01W243E35
*1 Shift Solenoid Valve SLU
*2 Transaxle Assembly

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SLU)


    1. A01W5LWE46
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Wire)

      Remove the TCM from the transaxle.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      11 (SLU+) - 5 (SLU-) 20°C (68°F) 5.0 to 5.6 Ω
      11 (SLU+) - Body ground and other terminals Always 10 kΩ or higher
      5 (SLU-) - Body ground and other terminals Always 10 kΩ or higher

    OK
    NG
  2. INSPECT SHIFT SOLENOID VALVE SLU


    1. A01W2VBE46
      Text in Illustration
      *1 Shift Solenoid Valve SLU

      Remove shift solenoid valve SLU.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.

      OK
      Valve moves and makes an operating sound.

    OK
    NG