THERMOSTAT INSPECTION

PROCEDURE


  1. INSPECT THERMOSTAT

    Tech Tips

    The valve opening temperature is inscribed on the thermostat.

    A01W1JZ

    1. A01VZZ6

      Immerse the thermostat in water, and then gradually heat the water.

    2. Check that the valve of the thermostat opens at the specified temperature.

      Standard valve opening temperature
      80 to 84°C (176 to 183°F)

      If the valve does not open as specified, replace the thermostat.

    3. A01W1W4E02
      Text in Illustration
      *a Valve Lift

      Check the valve lift.

      Standard valve lift
      10 mm (0.394 in.) or more at 95°C (203°F)

      If the valve lift is not as specified, replace the thermostat.

    4. Check that the valve is fully closed when the thermostat is at a low temperature (below 77°C (171°F)).