CRANKSHAFT POSITION SENSOR INSPECTION

PROCEDURE


  1. INSPECT CRANK POSITION SENSOR


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Temperature Specified Condition
      Cold 1630 to 2740 Ω
      Hot 2065 to 3225 Ω

      Tech Tips

      "Cold" and "Hot" mean the temperature of the coils themselves. "Cold" is from -10 to 50°C (14 to 122 °F) and "Hot" is from 50 to 100°C (122 to 212°F).

      If the resistance is not as specified, replace the crank position sensor.