INTEGRATION RELAY INSPECTION

PROCEDURE


  1. INSPECT NO. 1 INTEGRATION RELAY

    A01W3EXE08
    Text in Illustration
    *1 No. 1 Integration Relay - -

    1. EFI MAIN RELAY:


      1. A01W2IOE08

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1B-1 - 1A-8 Battery voltage is not applied between terminals 1C-7 and 1E-2 10 kΩ or higher
        1B-1 - 1A-8 Battery voltage is applied between terminals 1C-7 and 1E-2 Below 1 Ω
        1B-1 - 1C-3
        1B-1 - 1C-4
        1B-1 - 1C-6
        1B-1 - 1C-9
        1B-1 - 1C-10
        Text in Illustration
        *1

        Component without harness connected

        (No. 1 Integration Relay)

        If the resistance is not as specified, replace the No. 1 integration relay.

    2. A/F HTR RELAY:


      1. A01W2IOE08

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1A-6 - 1D-1 Battery voltage is not applied between terminals 1A-8 and 1E-2 10 kΩ or higher
        1A-6 - 1D-1 Battery voltage is applied between terminals 1A-8 and 1E-2 Below 1 Ω
        1A-7 - 1D-1
        Text in Illustration
        *1

        Component without harness connected

        (No. 1 Integration Relay)

        If the resistance is not as specified, replace the No. 1 integration relay.

    3. IG2 RELAY:


      1. A01W2IOE08

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1A-1 - 1D-3 Battery voltage is not applied between terminals 1C-8 and 1E-2 10 kΩ or higher
        1A-1 - 1D-3 Battery voltage is applied between terminals 1C-8 and 1E-2 Below 1 Ω
        1A-3 - 1D-3
        1A-5 - 1D-3
        1C-1 - 1D-3
        1C-2 - 1D-3
        1C-5 - 1D-3
        Text in Illustration
        *1

        Component without harness connected

        (No. 1 Integration Relay)

        If the resistance is not as specified, replace the No. 1 integration relay.