6AR-FSE BATTERY / CHARGING SERVICE DATA

Battery Standard voltage 12.6 to 12.8 V at 20°C (68°F)
Charging circuit without load Standard amperage 10 A or higher
Standard voltage 12.1 to 15.4 V
Charging circuit with load Standard amperage 30 A or higher
Generator brush holder assembly Brush length Standard length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum length 4.5 mm (0.177 in.)
Generator rotor assembly Standard resistance Slip ring 1.5 to 1.9 Ω at 20°C (68°F)
Slip ring - Rotor 10 MΩ or higher
Slip ring diameter Standard diameter 14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum diameter 14.0 mm (0.551 in.)