6AR-FSE COOLING SERVICE DATA

THERMOSTAT
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10 to 14 mm (0.394 to 0.551 in.) at 95°C (203°F)
COOLING FAN MOTOR
Item Condition Specified Condition
Cooling fan motor Battery voltage applied at 20°C (68°F) 5.5 to 7.5 A
No. 2 cooling fan motor Battery voltage applied at 20°C (68°F) 5.5 to 7.5 A
RELAY
Item Tester Connection Specified Condition
Fan relay 3 - 4

Below 1 Ω

(Battery voltage not applied between terminals 1 and 2)

3 - 5

10 kΩ or higher

(Battery voltage not applied between terminals 1 and 2)

3 - 4

10 kΩ or higher

(Battery voltage is applied between terminals 1 and 2)

3 - 5

Below 1 Ω

(Battery voltage is applied between terminals 1 and 2)

RADIATOR
Item Condition Specified Condition
Radiator cap sub-assembly Standard pressure (for brand-new radiator cap sub-assembly)

93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18.0 psi)

Minimum pressure (for used radiator cap sub-assembly)

79 kPa (0.8 kgf/cm2, 11.5 psi)