RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT H-LP RELAY


    1. A01W5KYE20

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage is applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the H-LP relay.

  2. INSPECT FR FOG RELAY (for 6AR-FSE)


    1. A01W1HWE36

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the FR FOG relay.