POWER WINDOW REGULATOR MOTOR(for Front Door) INSPECTION

PROCEDURE


  1. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH


    1. A01W1BOE15
      Text in Illustration
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly LH)

      *b Clockwise
      *c Counterclockwise
      *d Motor Gear

      Apply positive (+) battery voltage to connector terminal 2 (B).

      Note

      Do not apply positive (+) battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a ground lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that the motor gear rotates smoothly as follows:

      OK
      Measurement Condition Specified Condition

      1. Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 10 (UP).

      3. Disconnect and reconnect the negative (-) battery lead for terminal 10 (UP) within 1 second.

      Motor gear rotates clockwise

      1. Connect the positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 7 (DOWN).

      3. Disconnect and reconnect the negative (-) battery lead for terminal 7 (DOWN) within 1 second.

      Motor gear rotates counterclockwise

      • If the result is not as specified, replace the power window regulator motor assembly LH.

      Note

      Initialize the power window control system after installing the power window regulator motor and regulator assembly onto the door.

  2. INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH


    1. A01W155E13
      Text in Illustration
      *a

      Component without harness connected

      (Power Window Regulator Motor Assembly RH)

      *b Clockwise
      *c Counterclockwise
      *d Motor Gear

      Apply positive (+) battery voltage to connector terminal 2 (B).

      Note

      Do not apply positive (+) battery voltage to any terminals other than terminal 2 (B) to avoid damaging the pulse sensor inside the motor.

    2. Connect a ground lead to connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).

    3. Check that the motor gear rotates smoothly as follows:

      OK
      Measurement Condition Specified Condition

      1. Connect the positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 10 (UP).

      3. Disconnect and reconnect the negative (-) battery lead for terminal 10 (UP) within 1 second.

      Motor gear rotates counterclockwise

      1. Connect a positive (+) battery lead to terminal 2 (B), connect a negative (-) battery lead to terminal 1 (GND), and keep them connected for 3 seconds or more.

      2. With terminals 2 (B) and 1 (GND) connected, connect a negative (-) battery lead to terminal 7 (DOWN).

      3. Disconnect and reconnect the negative (-) battery lead for terminal 7 (DOWN) within 1 second.

      Motor gear rotates clockwise

      • If the result is not as specified, replace the power window regulator motor assembly RH.

      Note

      Initialize the power window control system after installing the power window regulator motor and regulator assembly onto the door.