COMPRESSOR(for 2AR-FE) INSPECTION

PROCEDURE


  1. INSPECT COMPRESSOR ASSEMBLY WITH PULLEY (COMPRESSOR SOLENOID)


    1. A01VZONE14
      Text in Illustration
      *a

      Component without harness connected

      (Compressor Assembly with Pulley (Compressor Solenoid))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (SOL-) - 2 (SOL+) 20°C (68°F) 10.1 to 11.1 Ω

      If the resistance is not as specified, replace the compressor assembly with pulley.