PROCEDURE
INSTALL COOLER EXPANSION VALVE
Apply sufficient compressor oil to 2 new O-rings and the fitting surfaces of the cooler expansion valve.
| Compressor oil |
|---|
| ND-OIL 8 or equivalent |
Install 2 new O-rings to the No. 1 cooler evaporator sub-assembly.
Using a 4 mm hexagon wrench, install the cooler expansion valve with the 2 hexagon bolts.
CONNECT AIR CONDITIONER TUBE AND ACCESSORY ASSEMBLY
CONNECT SUCTION PIPE SUB-ASSEMBLY
INSTALL FRONT OUTER COWL TOP PANEL SUB-ASSEMBLY
for LHD: Click here
for RHD: Click here
INSTALL WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
WARM UP ENGINE
INSPECT FOR REFRIGERANT LEAK