PROCEDURE
INSTALL EVAPORATOR TEMPERATURE SENSOR (NO. 1 COOLER THERMISTOR)
except Cold Storage Evaporator:
| *a | Fixed Part |
| *b | Sensor Part |
Install the evaporator temperature sensor (No. 1 cooler thermistor) as shown in the illustration.
| Part | Length | |
|---|---|---|
| A | 34.3 mm | 1.35 in. |
| B | 20.9 mm | 0.823 in. |
| C | 50.0 mm | 1.97 in. |
Note
Be sure to insert the evaporator temperature sensor (No. 1 cooler thermistor) only once because reinserting it into the same position will not allow it to be firmly secured.
When reusing the No. 1 cooler evaporator sub-assembly, insert the sensor part of the evaporator temperature sensor (No. 1 cooler thermistor) one row from the row that has been used previously (X in the illustration).
After inserting the evaporator temperature sensor (No. 1 cooler thermistor), do not apply excessive force to the wire.
Directly insert the evaporator temperature sensor (No. 1 cooler thermistor) until the edge of plastic case "a" comes into contact with No. 1 cooler evaporator sub-assembly "b".
for Cold Storage Evaporator:
| *a | Fixed Part |
| *b | Sensor Part |
Install the evaporator temperature sensor (No. 1 cooler thermistor) as shown in the illustration.
| Part | Length | |
|---|---|---|
| A | 67.8 mm | 2.67 in. |
| B | 41.0 mm | 1.61 in. |
| C | 50.0 mm | 1.97 in. |
| D | 40.0 mm | 1.57 in. |
| E | 25.0 mm | 0.984 in. |
Note
Be sure to insert the evaporator temperature sensor (No. 1 cooler thermistor) only once because reinserting it into the same position will not allow it to be firmly secured.
When reusing the No. 1 cooler evaporator sub-assembly, insert the sensor part of the evaporator temperature sensor (No. 1 cooler thermistor) 3 rows from the row that has been used previously (X in the illustration).
After inserting the evaporator temperature sensor (No. 1 cooler thermistor), do not apply excessive force to the wire.
Directly insert the evaporator temperature sensor (No. 1 cooler thermistor) until the edge of plastic case "a" comes into contact with No. 1 cooler evaporator sub-assembly "b".
INSTALL NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY
INSTALL COOLER EXPANSION VALVE
INSTALL HEATER PACKING
INSTALL AIR CONDITIONING HARNESS ASSEMBLY
INSTALL BLOWER ASSEMBLY
for LHD: Click here
for RHD: Click here
INSTALL AIR CONDITIONING UNIT ASSEMBLY