PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
REMOVE PIPING CLAMP
While pressing the end of the No. 1 cooler refrigerant suction hose into the end of the suction pipe sub-assembly, use pliers to squeeze together both sides of the piping clamp until it breaks apart.
| *1 | Suction Pipe Sub-assembly | *2 | No. 1 Cooler Refrigerant Suction Hose |
| *3 | Piping Clamp | - | - |
| *a | Press in | - | - |
Note
If any foreign matter is adhered to the connecting part, brush it off or use compressed air to remove it.
Make sure that fragments of the piping clamp do not enter the piping.
Separate the No. 1 cooler refrigerant suction hose.
Note
Clean off any moisture or foreign matter near the ends of the No. 1 cooler refrigerant suction hose and suction pipe sub-assembly.
Remove the 2 O-rings from the No. 1 cooler refrigerant suction hose.
Note
Wrap the open ends of the separated suction pipe sub-assembly and No. 1 cooler refrigerant suction hose with vinyl tape to prevent the entry of moisture and foreign matter.