REFRIGERANT LINE REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

    Click here

  2. REMOVE PIPING CLAMP


    1. While pressing the end of the No. 1 cooler refrigerant suction hose into the end of the suction pipe sub-assembly, use pliers to squeeze together both sides of the piping clamp until it breaks apart.

      A01W3QRE01
      Text in Illustration
      *1 Suction Pipe Sub-assembly *2 No. 1 Cooler Refrigerant Suction Hose
      *3 Piping Clamp - -
      *a Press in - -

      Note


      • If any foreign matter is adhered to the connecting part, brush it off or use compressed air to remove it.

      • Make sure that fragments of the piping clamp do not enter the piping.

    2. Separate the No. 1 cooler refrigerant suction hose.

      Note

      Clean off any moisture or foreign matter near the ends of the No. 1 cooler refrigerant suction hose and suction pipe sub-assembly.

    3. Remove the 2 O-rings from the No. 1 cooler refrigerant suction hose.

      Note

      Wrap the open ends of the separated suction pipe sub-assembly and No. 1 cooler refrigerant suction hose with vinyl tape to prevent the entry of moisture and foreign matter.