1GD-FTV COOLING SERVICE DATA

THERMOSTAT
Standard Valve Opening Temperature Standard Valve Lift
80 to 84°C (176 to 183°F) 10 mm (0.394 in.) or more at 95°C (203°F)
COOLING FAN SWITCH
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 2.32 to 2.59 kΩ
80°C (176°F) 0.310 to 0.326 kΩ
RADIATOR CAP
Item Specified Condition

Standard Valve

(for brand-new cap)

93 to 123 kPa (1.0 to 1.3kgf/cm2, 13.5 to 18 psi)

Minimum Standard Valve

(for used cap)

79 kPa (0.8 kgf/cm2, 11.4 psi)