KINETIC DYNAMIC SUSPENSION SYSTEM, Diagnostic DTC:C1831/31 and C1832/32
| DTC Code | DTC Name |
|---|---|
| C1831/31 | Accumulator Solenoid Malfunction / Upside |
| C1832/32 | Accumulator Solenoid Malfunction / Downside |
DESCRIPTION
The stabilizer control ECU receives information from the steering angle sensor, skid control ECU (speed signal) and yaw rate and acceleration sensor via CAN communication. Based on this information, the stabilizer control ECU turns the stabilizer control solenoid valve (built into the stabilizer control with accumulator housing assembly) on or off.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
|---|---|---|---|
C1831/31 |
Accumulator Solenoid Malfunction / Upside |
Either condition is met:
|
|
C1832/32 |
Accumulator Solenoid Malfunction / Downside |
Either condition is met:
|
|
WIRING DIAGRAM
PROCEDURE
READ VALUE USING INTELLIGENT TESTER (ACCUMULATOR VALVE)
Turn the engine switch off.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Chassis / KDSS / Data List.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
Chassis > KDSS > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Accumulator Valve (Downside)
Stabilizer control solenoid valve (for Lower Chamber)
ON or OFF
ON: Stabilizer control solenoid valve closed
OFF: Stabilizer control solenoid valve open
-
Accumulator Valve (Upside)
Stabilizer control solenoid valve (for Upper Chamber)
ON or OFF
ON: Stabilizer control solenoid valve open
OFF: Stabilizer control solenoid valve closed
-
Perform the Active Test of the stabilizer control ECU using the intelligent tester.
Chassis > KDSS > Active Test
Tester Display
Measurement Item
Control Range
Diagnostic Note
Accumulator Valve (Upside)
Stabilizer control solenoid valve (for Upper Chamber)
Valve ON / OFF
The operating sound of the solenoid (clicking sound) can be heard
ON: Data List ON
OFF: Data List OFF
When the Active Test is performed, the solenoid turns on for 3 seconds.
Accumulator Valve (Downside)
Stabilizer control solenoid valve (for Lower Chamber)
Valve ON / OFF
The operating sound of the solenoid (clicking sound) can be heard
ON: Data List ON
OFF: Data List OFF
When the Active Test is performed, the solenoid turns on for 3 seconds.
Chassis > KDSS > Active Test
Active Test Display
Accumulator Valve (Downside)
Data List Display
Accumulator Valve (Downside)
Chassis > KDSS > Active Test
Active Test Display
Accumulator Valve (Upside)
Data List Display
Accumulator Valve (Upside)
Check that the solenoid operating sound can be heard, and that the Data List display changes between ON and OFF in response to the Active Test.
OK
Solenoid operating sound can be heard and display changes between ON and OFF in response to Active Test.
Result
Result
OK
NG
NG CHECK HARNESS AND CONNECTOR (STABILIZER CONTROL ECU - STABILIZER CONTROL SOLENOID VALVE)Click here
RECONFIRM DTC
Clear the DTCs.
Chassis > KDSS > Clear DTCs
Check for DTCs.
Result
Result
Proceed to
DTC is output
A
DTC is not output
B
Chassis > KDSS > Trouble Codes
CHECK HARNESS AND CONNECTOR (STABILIZER CONTROL ECU - STABILIZER CONTROL SOLENOID VALVE)
Disconnect the stabilizer control ECU connector.
Disconnect the stabilizer control with accumulator housing assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
G57-3 (SLAU) - R23-6 (SLAU)
Always
Below 1 Ω
G57-3 (SLAU) - Body ground
Always
10 kΩ or higher
G57-1 (SLAL) - R23-5 (SLAL)
Always
Below 1 Ω
G57-1 (SLAL) - Body ground
Always
10 kΩ or higher
R23-4 (AUG) - Body ground
Always
Below 1 Ω
Result
Result
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
INSPECT STABILIZER CONTROL SOLENOID VALVE
Disconnect the stabilizer control with accumulator housing assembly connector.
-
*a
Component without harness connected
(Stabilizer Control with Accumulator Housing Assembly)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Table 1. C1831/31 (for Upper Chamber) Tester Connection
Condition
Specified Condition
5 (SLAL) - 4 (AUG)
25°C (77°F)
24.3 to 25.7 Ω
Table 2. C1832/32 (for Lower Chamber) Tester Connection
Condition
Specified Condition
6 (SLAU) - 4 (AUG)
25°C (77°F)
24.3 to 25.7 Ω
-
*a
Component without harness connected
(Stabilizer Control with Accumulator Housing Assembly)
Check for an operating sound of the stabilizer control solenoid valve.
for Upper Chamber:
Connect terminal 5 (SLAL) to the positive (+) battery terminal, and terminal 4 (AUG) to the negative (-) battery terminal.
OK
An operating sound (click sound) can be heard.
-
*a
Component without harness connected
(Stabilizer Control with Accumulator Housing Assembly)
for Lower Chamber:
Connect terminal 6 (SLAU) to the positive (+) battery terminal, and terminal 4 (AUG) to the negative (-) battery terminal.
OK
An operating sound (click sound) can be heard.
Result
Result
OK
NG