REFRIGERANT LINE REMOVAL

PROCEDURE

  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

    1. for HFC-134a (R134a):

      Click here

    2. for HFO-1234yf (R1234yf):

      Click here

  2. REMOVE PIPING CLAMP

    1. E273283C02

      *1

      Suction Pipe Sub-assembly

      *2

      Liquid Tube Sub-assembly

      Install SST to the piping clamp as shown in the illustration.

      09870-00025

    2. E273284C02

      *a

      Push in

      Hold the liquid tube sub-assembly and suction pipe sub-assembly with each hand and push in SST with both thumbs.

      Note:

      Do not apply excessive force to the liquid tube sub-assembly or suction pipe sub-assembly as they may bend.

    3. E273285C02

      *1

      Suction Pipe Sub-assembly

      *a

      Stopper

      *b

      Pull off

      Raise the stopper of SST and remove SST and the piping clamp together from the suction pipe sub-assembly.

    4. Remove the piping clamp from SST.

    5. Remove the liquid tube sub-assembly from the suction pipe sub-assembly.

    6. Remove the 2 O-rings from the liquid tube sub-assembly.

      Note:

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.