REFRIGERANT LINE REMOVAL
PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
for HFC-134a (R134a):
for HFO-1234yf (R1234yf):
REMOVE PIPING CLAMP
-
*1
Suction Pipe Sub-assembly
*2
Liquid Tube Sub-assembly
Install SST to the piping clamp as shown in the illustration.
09870-00025
-
*a
Push in
Hold the liquid tube sub-assembly and suction pipe sub-assembly with each hand and push in SST with both thumbs.
Note:Do not apply excessive force to the liquid tube sub-assembly or suction pipe sub-assembly as they may bend.
-
*1
Suction Pipe Sub-assembly
*a
Stopper
*b
Pull off
Raise the stopper of SST and remove SST and the piping clamp together from the suction pipe sub-assembly.
Remove the piping clamp from SST.
Remove the liquid tube sub-assembly from the suction pipe sub-assembly.
Remove the 2 O-rings from the liquid tube sub-assembly.
Note:Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
-