SPEED SENSOR INSPECTION

PROCEDURE


  1. INSPECT TRANSMISSION REVOLUTION SENSOR (NT)


    1. A004IXUE04
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Revolution Sensor (NT))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 560 to 680 Ω

      If the result is not as specified, replace the transmission revolution sensor (NT).

  2. INSPECT TRANSMISSION REVOLUTION SENSOR (SP2)


    1. A004IXUE04
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Revolution Sensor (SP2))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 560 to 680 Ω

      If the result is not as specified, replace the transmission revolution sensor (SP2).