DATA LIST
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Tech Tips
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Connect the GTS to the DLC3.
Turn the ignition switch ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) |
- | - |
| Evaporator Fin Thermistor | No. 1 cooler thermistor (evaporator temperature sensor) | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | *2 |
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | *2 |
| Regulator Control Current | Solenoid valve control current | Min.: 0 A Max.: 0.997 A |
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation | *2 |
| Electric Heater Count | Maximum electric heater operation level | Min.: 0 Max.: 3 |
Maximum possible operation level of electric heater displayed | *1 |
| Electric Heater Active Level | Actual electric heater operation level | Min.: 0 Max.: 3 |
Actual operation level of electric heater displayed | *1 |
| A/C Cutoff Signal | A/C control cutoff signal | ON or OFF | A/C switch on: OFF A/C switch off: ON |
*2 |
| Refrigerant Gas Type | Refrigerant gas type | R134a or 1234yf | Refrigerant gas type displayed | *2 |
| Number of Trouble Codes | Number of trouble codes | Min.: 0 Max.: 255 |
Number of DTCs displayed | - |
| Upper Air Mix Target Position (Driver Side) | No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) target position | Min.: 0 Max.: 100 |
|
- |
| Upper Air Mix Current Position (Driver Side) | No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) current position | Min.: 0 Max.: 100 |
|
- |
| Lower Air Mix Target Position (Driver Side) | No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) target position | Min.: 0 Max.: 100 |
|
- |
| Lower Air Mix Current Position (Driver Side) | No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) current position | Min.: 0 Max.: 100 |
|
- |
| Front Air Outlet Target Position | No. 2 air conditioning radiator damper servo sub-assembly (mode switching) target position | Min.: 0 Max.: 100 |
|
- |
| Front Air Outlet Current Position | No. 2 air conditioning radiator damper servo sub-assembly (mode switching) actual position | Min.: 0 Max.: 100 |
|
- |
| Air Inlet Target Position | No. 1 blower damper servo sub-assembly target position | Min.: 0 Max.: 100 |
w/o Headlight Cleaner System
w/ Headlight Cleaner System
|
- |
| Air Inlet Current Position | No. 1 blower damper servo sub-assembly current position | Min.: 0 Max.: 100 |
w/o Headlight Cleaner System
w/ Headlight Cleaner System
|
- |
| Engine Coolant Temperature | Engine coolant temperature sensor | Min.: 0.5°C (32.9°F) Max.: 127.5°C (261.5°F) |
Actual engine coolant temperature displayed | - |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: 0 kPa Max.: 3760 kPa |
Actual refrigerant pressure displayed | - |
| Air Outlet Target Temperature (Driver Side) | Air outlet target temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual air outlet target temperature displayed | - |
*1: w/ PTC Heater
*2: w/ Cooler System
ACTIVE TEST
Tech Tips
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the ignition switch ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Magnetic Clutch Relay | Air conditioning system operation | OFF or ON | *2 |
| Heater Active Level | Quick heater assembly | OFF or ON | *1 |
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0 Max.: 100 |
Operates between 0 to 100% |
| Air Inlet | No. 1 blower damper servo sub-assembly (fresh/recirculation) | Min.: 0 Max.: 100 |
Operates between 0 to 100% |
| Air Outlet (Front) | No. 2 air conditioning radiator damper servo sub-assembly (mode switching) | Min.: 0 Max.: 100 |
Operates between 0 to 100% |
| Upper Air Mix (Driver Side) | No. 1 air conditioning radiator damper servo sub-assembly (upper air mix) | Min.: 0 Max.: 100 |
Operates between 0 to 100% |
| Lower Air Mix (Driver Side) | No. 1 air conditioning radiator damper servo sub-assembly (lower air mix) | Min.: 0 Max.: 100 |
Operates between 0 to 100% |
*1: w/ PTC Heater
*2: w/ Cooler System