VACUUM REGULATING VALVE REMOVAL

PROCEDURE

  1. REMOVE WINDSHIELD WIPER MOTOR AND LINK ASSEMBLY

  2. REMOVE WATER GUARD PLATE LH (for LHD)

  3. REMOVE WATER GUARD PLATE LH (for RHD)

  4. REMOVE NO. 2 HEATER AIR DUCT SPLASH SHIELD SEAL (for LHD)

  5. REMOVE NO. 2 HEATER AIR DUCT SPLASH SHIELD SEAL (for RHD)

  6. REMOVE OUTER COWL TOP PANEL (for LHD)

  7. REMOVE OUTER COWL TOP PANEL (for RHD)

  8. REMOVE VACUUM REGULATING VALVE ASSEMBLY

    1. A353296C02

      *1

      No. 2 Vacuum Transmitting Hose Assembly

      *2

      No. 3 Vacuum Transmitting Hose Assembly

      Disconnect the vacuum regulating valve assembly connector.

    2. Disconnect the No. 2 vacuum transmitting hose assembly and No. 3 vacuum transmitting hose assembly from the vacuum regulating valve assembly.

    3. Remove the 2 bolts and vacuum regulating valve assembly from the No. 2 vacuum switching valve bracket.